Assembly and connection
24
02.00 | KSP3, KSP3-LH, KSP3-F | Assembly and Operating Manual | en |
1463318
In doing so, the transfer dimensions ØC, D, E and F must be
observed.
Dynamic pressure monitoring of the workpiece flat work surface
For this purpose, the customer must provide the top jaw with a Ø2
mm monitoring hole on the workpiece flat work surface. This
ensures that the escaping air pressure can be released up to where
contact is made with the mounted workpiece and that a
differential pressure measurement can be carried out via a
differential pressure switch.
In doing so, the transfer dimensions ØC, D, E and F must be
observed.
Max. pressure 2 bar.
Limit volumetric flow to 10 l/min