02.00 | KSP3, KSP3-LH, KSP3-F | Assembly and Operating Manual | en |
1463318
27
Troubleshooting
Possible cause
Solution(s)
The monitoring piece in a base jaw is
pressed too tightly against the housing
Loosen the adjustment screws and readjust the
monitoring piece
}
7 [
/
28]
Monitoring functions of the jaw stroke positions do not work
properly
Possible cause
Solution(s)
Monitoring pieces in the base jaws not
positioned exactly
Readjust monitoring piece for the required
function
}
7 [
/
28]
Pressure change due to clamping
stroke too low
Adjust clamping stroke to the workpiece to >0.3
mm/jaw
Seals damaged
Replace seals in cover and adapter
plate
}
8.1 [
/
37]