Assembly and settings
4.4.3 OSE 63
Adjustment of 0° and 180° end positions
1. Set connection A under pressure until product unit reaches its
end position.
2. Loosen the counter-nut (53) at B and set the end position by
turning the sleeve (10).
3. Fasten counter-nut (53) and check end position.
4. Repeat same procedure for second end stop.