108
12.00 | SWS | Assembly and Operating Manual | en | 389456
Mount new sensor assembly
Ø Screw hexagon nut(6) onto new sensor(2) or(5).
Ø Screw new sensor(2) or(5) into SWK(3) until sensor(2) or(5)
touches the detection shaft.
Ø Unscrew sensor(2) or(5) by half a turn.
Ø Hold sensor(2) or(5) in this position and connect sensor cable.
The sensor LED will illuminate.
Ø Apply screw lock to the thread of the sensor(2) or(5).
Ø Tighten the hexagon nut(6).
Max. tightening torque: 0.9Nm
Check new sensor assembly
Ø Connect all compressed air lines.
Ø Attach the adapter plate(1) to the SWK(3) with screws(4).
Max. tightening torque: 1.7Nm
Ø Secure the sensor cable to the adapter plate(1).
Ø Lock and unlock the locking piston and check the signals of the
sensors.