6.2 Braking system fault of the bender
Phenomenon
Cause
Solution
The indicators conversion of
BLPS is normal, but the bender
does not operate
The connection between the
control output of BLPS and
the electrical system of the
bender is open or wrong.
Check the control output circuits
The electrical trouble of the
bender
Check the circuits of the bender
The indicators conversion of
BLPS is normal, if the beam is
blocked, the bender cannot
stop.
The electrical trouble of the
bender
Check the circuits of the bender
The braking failure of the
bender
Check the bender
The indicators conversion of
BLPS is normal. If the beam is
blocked, the bender can stop
immediately
The pulley of the bender
Check the bender