The fractions of the measuring values can be hidden by changing setting at the Custom Setting Function. Display setting
number 2 (fraction display) and then select 0 (ON) to display fraction and 1 (OFF) to hide fraction. (See P51 for details.)
Fraction hidden
Fractiondisplayed
4) Analog Scale
DependingontheMeasuringmode,thefollowingvalueswillbedisplayedinthescale.
•
Fvalue,Tvalue,EVvalue(forincident),EVvalue(forreected),illuminancelx
(lux),illuminancefc
Thefollowingisascaledisplayexample.
Analog Scale Display (F value) Example
Measured value pointer
Memorypointers
[Exampleofanalogscale
whenMid.ToneisNOTset]
Dynamic
range[-]
Dynamicrange[+]
Clippoingpoint[+]
Clippoing
point[-]
Measuring value pointer
Memorypointers
[Exampleofanalogscale
whenMid.Toneisset]
3-4-3. Measuring Function Selection Icon
Pressanyoneoftheiconstoexecutethatfunction.
1 2 3
No. Icon Explanation
1
Average/DEV icon
Touchtoaverageoneormorememorizedmeasurements(see6-3P45)or
toactivateContrastFunction(6-4P46).
2
Information icon
TouchtodisplayMeasuringmodeandmeterinformation(see3-5P20for
details)
3
Tool Box icon
TouchtodisplayToolBoxscreentosetvariousfunctions.(see3-6P20for
details)