5-2-4.
Cordless Multiple (Cumulative) Flash Mode
ThisMeasuringmodeisusedwhenthelightgeneratedbytheashisinadequate
forproperexposure.Therepeatedashpopscanbeaccumulateduntilthedesired
apertureisdisplayed.
Thecumulativecountisupto99times,anddisplayedintheTest/TitleeldontheLCD
screen.
Toactivatethismulti(cumulative)mode,setCordMultiple(Cumu.)FlashmodeONin
theCustomSetting(SeeP51fordetails).
Inthismeasuringmode,themeterissettomeasurestandbystatus(90seconds)by
pressingtheMeasuringbutton
8
onthesideofmeter,andduringthisstandbytime
retheashtotakemeasurements.Themeasuredvalue(f-stop)isdisplayedforeach
trigger of the ash.
1. TouchtheMeasuringmodeicontoopen
theMeasuringModeSelectionScreen,then
touch the icontoselectCordless
Multiple(Cumulative)FlashModeandreturn
the screen view to Measuring screen. (See
P25 for details.)
2. SettheISOsensitivityvalueonetheISO
icon.
3. Set the shutter speed on the T (shutter
speed) icon.
*
Besurethesettingsarewithinthe
specicationsoftheashequipment.
4. PresstheMeasuringbutton
8
on the side of
meter.
Themeterwillbeputintomeasuringstandby
modefor90secondsandthemeasuring
modeicon willblink,andtheilluminationof
LCDscreendimsnottoaffecttothereading.
5. Triggertheashunitmanuallywhilethe
Measuringmodeicon isblinking.
Thelightwillbemeasuredandthemeasured
value(f-stop)isdisplayed.
*
If90secondsperiodisexceededandthe
iconstopsblinkingbeforetheashhasbeen
triggered,presstheMeasuringbutton
8
againtoreturntoreadytomeasurestatus.
6. Evenaftermeasurement,the icon
continuesblinkingandthemeterisinready
tomeasurestatus.
7. Repeat this operation (pressing the
Measuringbutton
8
onthesideofmeter)
onlyforthenumberoftimesnecessary.
Theaccumulatedmeasuredvalue(f-stop)and
thenumberofcumulativeashesaredisplayed.
8. Torelease(cancel)themeasuringstandby
status while the icon isblinkingfor90
seconds,touchthescreen,orpresseither
theMemorybutton
5
orMenubutton
7
.
Setting
values
Percentage
of ash
Measuring screen
(Cordlessmulti
ashmode)
Measuring value (f-stop)