34
•
Shutter speed and f-stop (aperture) values can be displayed in full, 1/2 and 1/3 stop increments in Custom Setting. (See
P51 for details.)
•
After taking a measurement, changing T setting value will also change the measured value (f-stop).
•
After taking a measurement, changing ISO value will also change the measured value (f-stop).
•
Touching the Average/ΔEV button ( ) at the bottom of the screen activates the Contrast Function. (See P46 for
details.)
•
The Analog Scale display will change according to Measuring Mode, Incident/Reected and Mid-Tone mode selected
as well as “Set Analog Scale” in Menu list. (See P25 and P49 for details.)
•
See P38 for details about reading outside the display range or beyond the measuring range.
•
The shutter speeds that can be set will vary depending on the displayed step.
5-2-1. Cord (PC) Flash Mode
Inthismeasuringmode,asynchrocord(soldseparately)isusedtoconnecttheashto
themeter.UseCordModewhenyouneedtomeasuretototaloutputoftheashor
formeasuringashbulbs.
1. Connectthesynchrocord(soldseparately)to
themeter’ssynchroterminal
13
.
2. TouchtheMeasuringmodeicontoopenthe
MeasuringModeSelectionScreen,thentouch
the icontoselectCord(PC)Flash
Mode and return the screen view to Measuring
screen. (See P25 for details.)
3. SettheISOsensitivityvalueontheISOicon.
4. Set shutter speed on the T (shutter speed)
icon.
*Besurethesettingsarewithinthe
specicationsoftheashequipment.
5. PresstheMeasuringbutton
8
on the side of
meter.
Theashwillreandthemeasuredvalue
(f-stop)willbedisplayed.
•
The electronic ash unit may trigger when the meter or ash is turned ON or when the synchro cord is plugged into the
meter.
•
Triggering voltage is 2.0 to 300 volts. Below 2.0V, trigger the ash with Cordless Flash Mode (See P35 for details) or
Radio Flash Mode (Please refer to the Radio Control Flash Operating Manual).
•
When measuring a ash bulb, be sure to check the synchronization range and set the proper shutter speed.
Synchroterminal
13
Setting
values
Percentage
of ash
Measuring screen
[Cord(PC)FlashMode]
Measuring value (f-stop)

Table of Contents