2) HDCINEmode
ThisisameasuringexposureforHDVideo/DSLR
Cameras
1. TouchtheMeasuringmodeicontoopenthe
MeasuringModeSelectionScreen,then
touch the icontoselectHDCINE
Measuring Mode and return the screen view
to Measuring screen. (See P25 for details.)
2. Set the shutter speed on the T icon.
3. TouchtheISOicontoexpandit,andsetISO
sensitivityvalue.TheISOiconwillreturnto
itsreducedsizeafterasettingismadeand
theiconisnottouchedforashorttime.
4. Touchthef/sicontoexpandit,andsetframe
ratevalue.Thef/siconwillreturntoits
reducedsizeafterasettingismadeandthe
iconisnottouchedforashorttime.
5. Addanyltercompensationvaluetoadjust
the reading to the light source or lens
ltrationinuse.(seeP47fordetails.)
6. PresstheMeasuringbutton
8
on the side of
meter.
ReleasetheMeasuringbutton
8
to
completethemeasurement.Themeasured
f-stop(aperture)valueatthattimewillbe
displayed.
WhilepressingtheMeasuringbutton
8
,the
metermeasurescontinuouslyuntilitis
released.
•
Shutter speed and f-stop (aperture) values can be displayed in full, 1/2 and 1/3 stop increments in Custom Setting. (See
P51 for details.)
•
ISO850 can be selected at ISO sensitivity selection between ISO800 to ISO1000.
•
There are 20 preset of frame rates that can be set at “Edit Frame Rate” in the MENU list. (See P54 for details.)
•
After taking a measurement, changing a T setting value will also change the measured value (f-stop).
•
After taking a measurement, changing frame rate value will also change the measured value (f-stop).
•
After taking a measurement, changing ISO value will also change the measured value (f-stop).
•
Touching the Average/ΔEV button ( ) at the bottom of the screen activates the Contrast Function. (See P46 for
details.)
•
The Analog Scale display will change according to Measuring Mode, Incident/Reected and Mid-Tone mode selected
as well as “Set Analog Scale” in Menu list. (See P19 and P49 for details.)
•
See P38 for details about reading outside the display range or beyond the measuring range.
Setting
value
Measuring value
(illuminance)
MeasuringScreen(HDCINEMode)
Measuring value
(f-stop)