MX-5001N SIMULATION 6 – 120
60
60-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations (read/write)
of the MFP PWB image memory (SDRAM).
Section
Operation/Procedure
1) Press [EXECUTE] key.
Start the test.
60-2
Purpose
(This simulation is normally not used in the
market.)
Function (Purpose)
Used to set the MFP PWB onboard
SDRAM.
Section
Operation/Procedure
1) Select a target item of setting with [↑] [↓] key on the touch
panel.
2) Enter the set value with 10-key.
3) Press [OK] key.
NOTE: Set to the default value.
Result display Description
OK Success
NG Fail
NONE Not installed (Including DIMM trouble)
INVALID Execution disable
SLOT Description
SLOT1 System memory (expansion) DIMM1
SLOT2 System memory (standard) DIMM2
SLOT3 Local memory (MFP expansion) DIMM4
SLOT4 Local memory (MFP standard) DIMM3
SLOT5 Local memory (Codec standard) DIMM5
SLOT6 Local memory (ACREA standard) -
Item/Display Content
Setting
range
Default
value
ASETTING
ENABLE
DISABLE SDRAM
setting
change
flag
DDR
setting
of
Onboard
SPD
0 - 1 0 0
ENABLE DDR
setting
of B or
later
1
B NUMBER
OF ROW
11BIT ROW address
width
0 - 2 0 2
12BIT 1
13BIT 2
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
6'5$05($':5,7(7(67
(;(&87(
35(66>(;(&87(@7267$57
C NUMBER
OF
COLUMN
8BIT COLUMN address
width
0 - 4 0 2
9BIT 1
10BIT 2
11BIT 3
12BIT 4
DTWR
SETTING
VALUE
2CLOCK TWR set value 0 - 3 0 1
3CLOCK 1
4CLOCK 2
5CLOCK 3
E TRAS
SETTING
VALUE
4CLOCK TRAS set value 0 - 3 0 2
5CLOCK 1
6CLOCK 2
7CLOCK 3
F TRC
SETTING
VALUE
6CLOCK TRC set value 0 - 4 0 3
7CLOCK 1
8CLOCK 2
9CLOCK 3
10CLOCK 4
G TRCD
SETTING
VALUE
2CLOCK TRCD set value 0 - 3 0 1
3CLOCK 1
4CLOCK 2
5CLOCK 3
HTRP
SETTING
VALUE
2CLOCK TRP set value 0 - 3 0 1
3CLOCK 1
4CLOCK 2
5CLOCK 3
I TFRC
SETTING
VALUE
7CLOCK TFRC set value 0 -
13
03
8CLOCK 1
- -
20CLOCK 1
3
J CAS
LATENC
Y
CL=2 CAS latency 0 - 2 0 1
CL=2.5 1
CL=3 2
KTOTAL
NUMBER
OF
MBYTES
ON
BOARD
DDR
NONE Onboard DDR total
capacity
0 - 2 0 1
128M
BYTE
1
256M
BYTE
2
L NUMBER
OF ON
BOARD-
DDR
CS-BANK
NONE Onboard DDR bunk
number
0 - 2 0 1
1CHIP
SELECT
1
2CHIP
SELECT
2
Item/Display Content
Setting
range
Default
value
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
6'5$06(77,1*
$˖
˷ ˹
˖6(77,1*(1$%/(',6$%/(
$˖
˖180%(52)52:%,7
%˖
˖180%(52)&2/801%,7
&˖
˖7:56(77,1*9$/8(&/2&.
'˖
˖75&6(77,1*9$/8(&/2&.
)˖
˖75$66(77,1*9$/8(&/2&.
(˖
˖75&'6(77,1*9$/8(&/2&.
*˖
˖7536(77,1*9$/8(&/2&.
+˖
˖7)5&6(77,1*9$/8(&/2&.
,˖
˖&$6/$7(1&<&/
-˖
˖727$/180%(52)0%<7(621%2$5'''50%<7(
.˖
˖180%(52)21%2$5'''5&6%$1.&+,36(/(&7
/˖
2.