MX-5001N SIMULATION 6 – 121
61
61-1
Purpose
Operation test/check
Function (Purpose)
Used to check the LSU polygon motor rota-
tion and laser detection.
Section
LSU
Operation/Procedure
1) Press [EXECUTE] key.
When the operation is completed normally, [OK] is displayed.
In case of an abnormal end, [NG] is displayed.
61-3
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the laser power
Section
Operation/Procedure
1) Select a target mode for adjustment with [COPY] , [PR600/
FAX] and [PR1200] on the touch panel.
2) Select an adjustment target item with [↑] [↓] key on the touch
panel.
3) Enter the adjustment value using the 10-key.
4) Press [OK] key. (The set value is saved.)
When the laser power and the DUTY adjustment value are
increased, the print density is increased and the line width of
line images are increased.
Display Content
LSU TESTRESULT NG: PG Polygon mirror rotation abnormality
LSU TESTRESULT NG: K Laser abnormality (K)
LSU TESTRESULT NG: CL Laser light emitting abnormality (C,M,Y)
ǂǂǂ6,08/$7,21
ǂǂ12
&/26(
7(67
/687(67
(;(&87(
35(66>(;(&87(@7267$57
Mode Item/Display Content
Setting
range
De-fault value
Destination
linkage
41-sheet
machine
50-sheet
machine
COPY A LASER POWER MIDDLE (K1) Used to set the laser power (Middle speed/K1) 0 - 255 146
165 ✕
B LASER POWER MIDDLE (K2) Used to set the laser power (Middle speed/K2) 0 - 255 146
165 ✕
C LASER POWER MIDDLE (C1) Used to set the laser power (Middle speed/C1) 0 - 255 146
165 ✕
D LASER POWER MIDDLE (C2) Used to set the laser power (Middle speed/C2) 0 - 255 146
165 ✕
E LASER POWER MIDDLE (M1) Used to set the laser power (Middle speed/M1) 0 - 255 146
165 ✕
F LASER POWER MIDDLE (M2) Used to set the laser power (Middle speed/M2) 0 - 255 146
165 ✕
G LASER POWER MIDDLE (Y1) Used to set the laser power (Middle speed/Y1) 0 - 255 146
165 ✕
H LASER POWER MIDDLE (Y2) Used to set the laser power (Middle speed/Y2) 0 - 255 146
165 ✕
I LASER POWER LOW (K1) Used to set the laser power (Low speed/K1) 0 - 255 142
142 ✕
J LASER POWER LOW (K2) Used to set the laser power (Low speed/K2) 0 - 255 142
142 ✕
K LASER POWER LOW (C1) Used to set the laser power (Low speed/C1) 0 - 255 142
142 ✕
L LASER POWER LOW (C2) Used to set the laser power (Low speed/C2) 0 - 255 142
142 ✕
M LASER POWER LOW (M1) Used to set the laser power (Low speed/M1) 0 - 255 142
142 ✕
N LASER POWER LOW (M2) Used to set the laser power (Low speed/M2) 0 - 255 142
142 ✕
O LASER POWER LOW (Y1) Used to set the laser power (Low speed/Y1) 0 - 255 142
142 ✕
P LASER POWER LOW (Y2) Used to set the laser power (Low speed/Y2) 0 - 255 142
142 ✕
Q LASER POWER MIDDLE (BW1) Used to set the laser power (Middle speed/BW1) 0 - 255 146
165 ✕
R LASER POWER MIDDLE (BW2) Used to set the laser power (Middle speed/BW2) 0 - 255 146
165 ✕
S LASER POWER LOW (BW1) Used to set the laser power (Low speed/BW1) 0 - 255 142
142 ✕
T LASER POWER LOW (BW2) Used to set the laser power (Low speed/BW2) 0 - 255 142
142 ✕
U LASER DUTY MIDDLE (K) Laser DUTY select middle speed (K) 0 - 255 0
0 {
V LASER DUTY MIDDLE (C) Laser DUTY select middle speed (C) 0 - 255 0
0 {
W LASER DUTY MIDDLE (M) Laser DUTY select middle speed (M) 0 - 255 0
0 {
X LASER DUTY MIDDLE (Y) Laser DUTY select middle speed (Y) 0 - 255 0
0 {
Y LASER DUTY LOW (K) Laser DUTY select low speed (K) 0 - 255 0
0 {
Z LASER DUTY LOW (C) Laser DUTY select low speed (C) 0 - 255 0
0 {
AA LASER DUTY LOW(M) Laser DUTY select low speed (M) 0 - 255 0
0 {
AB LASER DUTY LOW(Y) Laser DUTY select low speed (Y) 0 - 255 0
0 {
AC LASER DUTY MIDDLE (BW) Laser DUTY select middle speed (BW) 0 - 255 0
0 {
AD LASER DUTY LOW (BW) Laser DUTY select low speed (BW) 0 - 255 0
0 {
1
: Oct. 24 2008
1