MX-M260/M310/M260N/M310N SIMULATION 6 - 31
Operation/procedure
1. Touch the item to be set.
The item and the currently set value are highlighted.
2. Press the [START] key.
The display is shifted to the copy menu.
3. Select the paper feed tray and the print density, and enter the
adjustment value with the 10-key.
4. Press the [START] key.
Copying is started.
Note: When this simulation is canceled, the display is shifted to the ini-
tial menu, but the machine is not reset.
Operation/procedure
1. Touch the item to be set.
The item and the currently set value are highlighted.
2. Press the [START] key.
The display is shifted to the copy menu.
3. Select the paper feed tray and the print density, and enter the
adjustment value with the 10-key.
4. Press the [START] key.
Copying is started.
Operation/procedure
1. The adjustment item and the currently set value are highlighted.
2. Enter the adjustment value with the 10-key.
Changes magnification ratio by changing speed of main motor.
The change of the paper transfer speed is 0.1% when changing value
is 1.
Operation/procedure
1. Select “1: COPY START.
The currently set value is highlighted beside the item.
2. Enter the set value of magnification with the 10-key, and press the
[#/P] key.
3. Press the [START] key.
Copying is started and the set value is stored.
There is no operation of tray selection.
The optimum paper tray for the scanned size is selected.
Even when the SPF/RSPF is selected, if there is no original on the
SPF/RSPF, the OC is scanned.
Even when the OC is selected, if there is any original on the SPF/
RSPF, the SPF/RSPF is scanned. (Setting 2)
48
48-1
Purpose Adjustment
Function
(Purpose)
Used to adjust the copy mode magnification ratio
(main scanning direction, sub scanning direction).
Section Image processing
Item Picture quality
Item Content
Setting
range
Default
1F-R
Main scanning magnification
ratio adjustment
1-99
50
2SCAN
Sub scanning magnification
ratio adjustment
60
3 SPF (SIDE1)
RSPF surface sub scan
magnification ratio
504 SPF (SIDE2)
RSPF back surface sub scan
magnification ratio
5 DUPLEX
DUPLEX sub scanning
magnification ratio adjustment
48-2
Purpose Adjustment
Function
(Purpose)
Used to adjust the scanner mode magnification ratio
(main/sub scanning direction).
Section Image processing
Item Picture quality
Item Content
Setting
range
Default
1
F-R
Main scanning magnification
ratio adjustment
1-99 50
2
SCAN
Sub scanning magnification
ratio adjustment
3
SPF (SIDE1)
RSPF surface sub scan
magnification ratio
4
SPF (SIDE2)
RSPF back surface sub scan
magnification ratio
48-3
Purpose Adjustment
Function
(Purpose)
Used to adjust the print mode magnification ratio
correction.
Section Image processing
Item Picture quality
Item Content
Setting
range
Default
1
145mm/s
Main motor speed (145mm/s)
45-55 50
2
122mm/s
Main motor speed (122mm/s)
48-8
Purpose Adjustment
Function
(Purpose)
FAX magnification adjustment (read)
Section FAX
Related soft SW SW112-1 to 8, SW113-1 to 8
Normal display NOW PRINTING
Error display
DOOR OPEN
JAM
PAPER EMPTY
Item Content
Setting
range
Default
1 COPY START Copy start
2
SCAN SELECT
(OC/SPF/RSPF)
Scan selection
(OC/ SPF/RSPF)
1-255* 128
3OC(MAIN)
SCAN Main scanning
magnification ratio
adjustment (OC)
1-255* 128
4OC(SUB)
SCAN Sub scanning
magnification ratio
adjustment (OC)
1-255* 128
5 SPF(MAIN)
SCAN Main scanning
magnification ratio
adjustment (SPF)
1-255* 128
6SPF(SUB)
SCAN Sub scanning
magnification ratio
adjustment (SPF)
1-255* 128
7 RSPF(MAIN)
SCAN Main scanning
magnification ratio
adjustment (RSPF)
1-255* 128
8 RSPF(SUB)
SCAN Sub scanning
magnification ratio
adjustment (RSPF)
1-255* 128