EasyManua.ls Logo

Sharp PC-1600 - Page 25

Sharp PC-1600
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PC-I600
Pin
Symbol
ln/Out
Active
Function
No.
level
53 KA2
Out
Low Goes low when the Z-80 1/0 28H-2FH is written.
54 KA1
Out Low
Goes low when the Z·80 1/0 28H-2FH is read.
55
KAO
Out Low
Goes low when the Z-80 1/0 60H-6FH is accessed.
56
CKO
Out
A 217KHz <pOSoutput. This signal is supplied to the HD61203 (S) LCD driver.
This signal is issued only when bit "b4" of the Z-80 1/0 37H is at "1 ",
Bit
"b4" is at "0" at power-on, but turns to "1" in the power-on routine to activate the
LCD.
57
i'öRP
Out Low Goes low when the Z-80 reads 33H of 1/0.
This signal is used by the Z-80 to read the return data from the LU57813P.
58 C/D
Out High Goes high when the Z-80 writes 3DH of 1/0.
Data are latched at a low to high transition of C/I:i. When the signal riseswith a half
clock delay from IORa, the data bus is stable.
59 10SU Out
Low
Goes low when the Z-80 1/0 20H-27H is accessed.
This signal is used for selection of the TC8576F UART.
60
E
Out
High Goes high when the Z-80 1/0 40H-5FH is accessed.
I
This signal is used to interface with the 6800 series LSI and is connected to the
HD61202 LCD driver input.
This signal is issuedwith a half clock delay slower than 10Ra.
.
61
DMEO
Out
High LH-5803 memory select signal.
This signal goes high when the LH·5803 accessesthe memorv,
62-70 PAO-PA7
'V
ln/Out
Corresponds to the port PA of the LH-5810 1/0 port.
This signal is used for the key strobe signal. To restore the original state of the low-
forced strobe signal, this signal must be turned high and then set in the input mode.
The input signal is pulled up internally.
65 VSS ±OV
71
PB2
'V
In Used for the cassette tape to reproduce a signal.
Pulled up internally.
72
PB5
'V
ln/Out
Used for an input port by the PC-1600.
Input to this line is a 1/64 second pulse which is issuedfrom the LU57813P sub-
controller. Pulled up internally.
73 PB6
'V
ln/Out
Used for the key strebe signal.
Application is the same as for the PA7-PAO.
Pulled up internally.
74 PB7
"'In
Receivesthe state of theIBREAK/ONlkey sent from the subcontroller.
Pulled down internally.
75
PC6 Out
Used by the Z-80 for a beep generation.
The following circuit is internally composed in the LSI.
PB2-
pe6'-
i\...
pe6
pe7'
/
SDO-
When either the PB2,
pes', pe7',
01'
SDO gaes lovv,
pes
becomes high.
To drive the buzzer, one of signals issuesa pulse.