2 Safety information
2.1 General safety notes
DANGER
If t
he safety component is integrated incorrectly, the dangerous state may be ended to
late.
b
Plan the integration of the safety component in accordance with the machine
requirements, see "Project planning", page 15.
2.2 Correct use
The C4-RD safety light curtain is an electro-sensitive protective device (ESPE) and is
suit
able for the following applications:
Hazardous point protection
Access protection
Hazardous area protection
The C4-RD safety light curtain must only be used within the limits of the prescribed and
s
pecified technical data and operating conditions at all times.
Any instance of improper use, incorrect modification, or manipulation of the C4-RD
safety light curtain shall void any warranty provided by SICK AG; furthermore, SICK AG
shall not accept any responsibility or liability for any resulting damage and consequen‐
tial damage.
2.3 Inappropriate use
The safety light curtain works as an indirect protective measure and cannot provide
pr
otection from parts thrown out nor from emitted radiation. Transparent objects are
not detected.
Among others, the C4-RD safety light curtain is not suitable for the following applica‐
tions:
Outdoors
Underwater
In explosion-hazardous areas
At altitudes over 3,000 m above sea level
In environments with increased levels of ionizing radiation
2.4 Requirements for the qualification of personnel
The safety light curtain must be planned in, installed, connected, commissioned and
ser
viced only by qualified safety personnel.
Project planning
F
or project planning, a person is considered competent when he/she has expertise and
experience in the selection and use of protective devices on machines and is familiar
with the relevant technical rules and national work safety regulations.
Mechanical mounting
F
or mechanical mounting, a person is considered competent when he/she has the
expertise and experience in the relevant field and is sufficiently familiar with the appli‐
cation of the protective device on the machine that he/she can assess its operational
safety status.
2 S
AFETY INFORMATION
8
O P E R A T I N G I N S T R U C T I O N S | C4-RD 8025644/19Z2/2021-03-09 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK C4-RD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4-RD and is the answer not in the manual?

SICK C4-RD Specifications

General IconGeneral
BrandSICK
ModelC4-RD
CategoryLighting Equipment
LanguageEnglish

Related product manuals