9 Operation
9.1 Overview
Information on the status as well as diagnostics and troubleshooting of the safety light
c
urtain can be displayed as follows:
Diagnostics LEDs
Status and fault information, as well as diagnostics data, are displayed directly on
the sender and receiver by means of the diagnostics LEDs.
NF
C
Status and fault information, as well as diagnostics data, can be read out to an
NF
C-capable device by means of an integrated NFC interface.
Complementary information
You can find additional information on NFC in the SICK Safety Assistant app.
Further topics
"Dia
gnostic LEDs", page 70
9.2 Safety
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Maintenance work, alignment work, fault diagnoses, and any changes to the
integration of the protective device in the machine must only be carried out by
qualified personnel.
b
The effectiveness of the protective device must be checked following such work.
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Make sure that the optical properties of the front screens of the sender and
receiver are not changed, e.g., by:
°
beading water, mist, frost, or ice formation. If applicable, remove films or
other types of contamination, disconnect the voltage supply of the receiver
and then switch it back on.
°
Scratches or damage. Replace the device whose front screen is scratched or
damaged.
b
Make sure that all reflective surfaces and objects maintain a minimum distance
from the protective field.
b
Make sure that no dispersive media (e.g., dust, fog, or smoke) are within the
calculated minimum distance from the protective field.
NOTE
T
his document does not provide instructions for operating the machine in which the
safety light curtain is integrated.
OPERATION 9
8027140/2021-11-04 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4
65
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4P-SA09031A00 and is the answer not in the manual?

SICK C4P-SA09031A00 Specifications

General IconGeneral
BrandSICK
ModelC4P-SA09031A00
CategorySafety Equipment
LanguageEnglish

Related product manuals