Minimum Typical Maximum
Shock resistance
5)
10 g, 16 ms (IEC 60068-2-27)
1)
The temperature difference between sender and receiver must not exceed 25 K.
2)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25 °C
.
3)
Maximum ambient operating temperature over 1,000 m above sea level: +50 °C.
Maximum ambient operating temperature over 2,000 m above sea level: +45 °C.
4)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
5)
Test conditions per axis: 1000 shocks.
13.2 Response time
Table 32: Response time for a single device
Protective field height in mm Response time in ms
Uncoded Code 1 or code 2
300 9 12
450 10 14
600 10 15
750 11 16
900 11 17
1050 11 18
1200 12 20
1350 12 21
1500 13 22
1650 13 23
1800 13 24
1950 14 25
2100 14 27
13.3 Power consumption
Table 33: Power consumption for sender and receiver
Protective field height in mm Typical power consumption for
sender in W
Typical power consumption for
sender in W
1)
Resolution 30 mm Resolution 30 mm
300 1.23 3.23
450 1.31 3.30
600 1.38 3.36
750 1.45 3.43
900 1.53 3.50
1050 1.60 3.56
1200 1.68 3.63
1350 1.75 3.69
1500 1.82 3.76
1650 1.90 3.83
1800 1.97 3.89
1950 2.05 3.96
13 TECHNICAL DATA
82
O P E R A T I N G I N S T R U C T I O N S | deTec4 8027140/2021-11-04 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4P-SA09031A00 and is the answer not in the manual?

SICK C4P-SA09031A00 Specifications

General IconGeneral
BrandSICK
ModelC4P-SA09031A00
CategorySafety Equipment
LanguageEnglish

Related product manuals