Figure 49: Example of use of deflector mirrors
Important information
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Only mount deflector mirrors to solid walls or machine components. The position
of the deflector mirrors must not change after alignment.
b
Do not use deflector mirrors if contamination, beading water, condensation, or
frost on the deflector mirrors is to be expected.
b
Make sure that the deflector mirrors are intact and free of scratches, contamina‐
tion, beading water, condensation, frost, etc. at all times.
Further topics
"Mir
ror columns", page 94
15.6.2 Mounting
To mount the deflector mirrors, use the included swivel mount brackets.
15.6.3 Change in scanning range using deflector mirrors
Important information
NOTE
T
he use of deflector mirrors reduces the scanning range depending on the number of
deflector mirrors in the protective field.
Table 55: Scanning range with and without 1 or 2 deflector mirrors
Type Solution Scanning
ran
ge, typi‐
cal
Scanning range with
1 deflector mirror, typi‐
cal
Scanning range with
2 deflector mirrors, typi‐
cal
PNS75, PNS125 30 mm 30 m D1 + D2 ≤ 27 m D1 + D2 + D3 ≤ 24.3 m
ACCESSORIES 15
8027140/2021-11-04 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4
93
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4P-SA09031A00 and is the answer not in the manual?

SICK C4P-SA09031A00 Specifications

General IconGeneral
BrandSICK
ModelC4P-SA09031A00
CategorySafety Equipment
LanguageEnglish

Related product manuals