8OPERATION
• PNP = Switching output in PNP circuit
• NPN = Switching output in NPN circuit
• DRV = Switching output in push/pull function
Switching output behavior
Level
SP
RP
active
Error signal
d
Switching output PNP NPN DRV Error status
Normally open/HNO
active U
v
0 V U
v
(PNP switched)
disabled
disabled 0 V
1)
U
v
2)
0 V (NPN switched)
1)
Pulldown only
2)
Pullup only
8.3.3 Normally closed with congurable hysteresis
Applications
− Overll protection
− Full signal
Conguration
Congure the Qx switching output as normally closed (using Q1 as an example).
Note:
The switching output designation (Q1 in the example here) changes according to the
selected process variable to be output.
1. Log in to Exprt mode, see “8.2.2 Exprt mode”.
2. Set the Output mode in the Q1-### / MODE1 / OUTPUT menu.
3. Congure the process variable to be output.
• Set the parameter to the required value in the Q1-### / PROC1 menu.
4. Set the Hysteresis mode in the Q1-### / OUT1 / HYST. menu.
5. Congure the switching output.
• Set the parameter to NC in the Q1-### / POL1 menu.