14 TECHNICAL DATA
14.4 Mechanics/materials
Materials in contact with the media Outer tube: polypropylene (PP-H)
G 3/4": PBT
3/4'' NPT: PBT
Easy Clamp Bracket: PP
Process connection G 3/4" A
3/4'' NPT
without process connection
Housing material PBT and PC
Max. probe load ≤ 4 Nm
Enclosure rating IP 65 / IP 67: EN 60529
Weight max. 500 g
14.5 Reference conditions
Air humidity 65% (± 20%)
Temperature 20 °C (± 5 °C)
Print Water (DC = 80)
Medium Distance to built-in components: 60 mm
Centered installation of sensor Distance to bottom of the tank: 10 mm
Container parameterization carried out CalEmp completed
14.6 Ambient conditions
Ambient temperature, operation
1)
–20 °C … +60 °C
Ambient temperature, storage –40 °C … +80 °C
1)
According to UL listing: degree of contamination 3 (UL61010-1: 2012-05); air humidity:
80% at temperatures up to 31 °C; installation height: max. 3,000 m above sea level; only for
indoor applications.