EasyManuals Logo

SICK CLV63 Series Technical Information

SICK CLV63 Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
5 Mounting
5.1 Overview of mounting procedure
Choose and prepare the mounting location.
Connect the connection cables at the protective housing via the protective double
bushing, seal the cable outlets and mount the protective double bushing on the
protective housing.
Mount the device on a bracket.
Align the device towards objects with bar code.
Adjust the device.
For mounting location, mounting, alignment and adjustment, see the operating instruc‐
tions of the respective bar code scanner.
5.2
Mounting requirements
The following tools and auxiliary equipment are required for mounting:
Lubricant such as Vaseline
Please observe the following:
Pay attention to the space requirements of the device. See type-specific dimen‐
sional drawing and reading field diagram.
Observe the technical data of the device.
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
Protect the device from direct sunlight.
Mount the device so that it is not exposed to shock and vibration.
Preferably route the connection cables downwards away from the device.
5.3 Mounting options
You can mount the device as follows:
Mount the device on an optional SICK bracket. The device is mounted on the
bracket by means of the 2 M5 threaded holes. For the optional SICK brackets, see
www.sick.com.
Mount the device on a user-supplied bracket. You can mount the device on the
bracket as follows:
With at least two M5 screws (in pairs) using two of the four 5.5 mm holes
Using the 2 M5 blind tapped holes
Dimensional drawings see "Design", page 11.
For an exact description of the device mounting procedure, see the operating instruc‐
tions of the respective bar code scanner.
Requirements for a user-supplied bracket
The brackets must meet the following requirements:
The bracket must be designed for the weight of the device including connection
cables, see "Technical data", page 27
The bracket must be able to support the device free of vibrations and oscillations.
It must be possible to adjust the bracket in x- and y-axes.
The bracket must have the required holes for mounting the device on the bracket.
MOUNTING 5
8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
19
Subject to change without notice

Other manuals for SICK CLV63 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV63 Series and is the answer not in the manual?

SICK CLV63 Series Specifications

General IconGeneral
BrandSICK
ModelCLV63 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals