Ambient data
CLV620
EMC test Radiated emission: in accordance with EN 61000-6-3 (2007-01)
Immunity: in accordance with EN 61000-6-2 (2005-08)
Vibration resistance EN 60068-2-6: 2008-02
Shock resistance EN 60068-2-27: 2009-05
Ambient operating tempera‐
ture
0 °C ... +40 °C
Storage temperature –20 °C ... +70 °C
Permissible relative humidity 0% ... 90%, non-condensing
Ambient light immunity 2,000 lx, on bar code
Bar code print contrast (PCS) 60%
7.2 Bar code scanner CLV63x in IP69K protective housing
NOTE
The relevant online data sheet for your product including technical data and dimen‐
sions can be downloaded from the Internet: www.sick.com/CLV63x
Optics
CLV630 CLV631 CLV632
Working range Long range Mid range Short range
Scanning method Line scanner, grid scanner
1)
, or line scanner with oscillating mirror, for identifier see type
code in operating instructions
Reading window orientation Front or side, for identifier see type code in operating instructions
Aperture angle Front reading window: 50°, side reading window: 51,5°
Scan/decoder frequency 400 Hz … 1,200 Hz
Resolution 0.2 mm ... 1.0 mm (type-dependent)
Focus Fixed focus
Light source Laser diode, visible red light (λ = 655)
MTTF (laser diode) 40,000 h at 25 °C
Laser class Class 2 in accordance with EN/IEC 60825-1:2014 (identical laser class to EN/IEC
60825-1:2007). Complies with 21 CFR 1040.10 except for tolerances according to Laser
Notice no. 50 of June 24, 2007 and its following versions.
Laser power (maximum/aver‐
age)
3.2 mW/ < 1.0 mW
Laser pulse duration < 300 μs
1)
Grid height approx. 15 mm at a reading distance of 200 mm
Performance
CLV630 CLV631 CLV632
Bar code types Code 39, code 128, code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode
Print ratio 2:1 ... 3:1
No. of codes per scan 1 ... 20 (standard decoder)
1 ... 6 (SMART decoder)
No. of codes per reading
interval
1)
1 ... 50 (auto-discriminating)
TECHNICAL DATA 7
8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
29
Subject to change without notice

Other manuals for SICK CLV63 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV63 Series and is the answer not in the manual?

SICK CLV63 Series Specifications

General IconGeneral
BrandSICK
ModelCLV63 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals