EasyManuals Logo

SICK CLV63 Series Technical Information

SICK CLV63 Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
CLV620
CAN Function: SICK CAN sensor network (master/slave, multiplexer/server)
Data transmission rate: 20 kbit/s ... 1 Mbit/s
Protocol: CSN (SICK CAN sensor network), CANopen
PROFINET PROFINET Dual Port optional over external fieldbus module CDF600-2
EtherCAT
®
Optional via external fieldbus module CDF600
PROFIBUS Optional via external fieldbus module CDF600-2
DeviceNet Optional over external connection module CDM420 + CMF fieldbus module
Digital switching inputs 2 (“Sensor 1”, “Sensor 2”), 2 additional inputs via CMC600 parameter cloning module in the
CDB650 or CDM420 connection module
Opto-decoupled, V
in
= max. 32 V, reverse polarity protected, can be wired via PNP output,
adjustable debouncing 0 ms ... 10,000 ms
Digital switching outputs 2 (“Result 1”, “Result 2”), 2 additional outputs via CMC600 parameter cloning module in the
CDB650 or CDM420 connection module
PNP, I
out
= max. 100 mA, short-circuit protected, pulse duration adjustable (static, 10 ms ...
10,000 ms)
Reading pulse Pulse sources for start: “Sensor 1” and/or “Sensor 2” switching inputs; command (data inter‐
face), auto pulse, CAN
Pulse sources for stop: reading cycle source, “Sensor 1”, “Sensor 2”, command, timer, condi‐
tion (e.g. Good Read)
Optical indicators Not accessible
Acoustic indicator None
Configuration SOPAS ET configuration software, profile programming with bar codes, command language,
GSD configuration
Mechanics/electronics
CLV620
Electrical connection Ethernet version: 2 x round connections (1 x male connector, M12, 17-pin, A-coded, 1 x
female connector, M12, 4-pin, D-coded)
Supply voltage 10 V DC ... 30 V DC, LPS or NEC Class 2, reverse polarity protected
Power consumption Max. 4.5 W with loaded switching outputs
Housing Stainless steel
Housing color Unpainted
Reading window material Plastic
Dimensions (L x W x H)
1)
85 mm x 84 mm x 154 mm
Weight
2)
854 g, with double protective bushing
Safety EN 60950-1
Electrical protection class III (EN 61140)
Enclosure rating IP69K (DIN 40050, Part 9)
Test conditions:
Water spray quantity: 14 ... 16 l/min
Water pressure/temperature: 10,000 KPa (100 bar) / 80 °C
Fan nozzle distance: 100 mm ... 150 mm
Spray angle: 0°, 30° , 60°, 90°
Cycle: 30 s for each position
Rotational speed of test specimen: 5 rpm
1)
See also see figure 5, page 11
2)
Without connecting cables
7 TECHNICAL DATA
28
T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK
Subject to change without notice

Other manuals for SICK CLV63 Series