Wire supply voltage for CLV69x-xxx0 in the CDB650-204 connection module
CLV69x-xxx0 (without heating)
CDB650-204
U
V
U
V
2
1
2
1
5
Shield
1 U
IN
2 GND
U
IN
*
GND
S1
F
Shield
M12, 17-pin, A-coded
Connection
“HOST/AUX/I/O”
GND
.
.
.
.
.
.
.
.
.
ON
OFF
S1: POWER
DC 18V ... 30V
U
IN
*
POWER
U
V
= DC 18V ... 30V at terminal U
IN
=
U
IN
* after switch S1, protected with internal fuse F
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
1) connection cable 1:1:
no. 6052286 (2m)
no. 6051194 (3m)
no. 6051195 (5m)
Switch S1:
ON:
Supply voltage U
IN
connected via fuse as U
IN
* to CDB650-204
and CLV69x.
Voltage U
IN
* can also be tapped at terminal 11 and 14.
OFF:
CDB650-204 and CLV69x separated from supply voltage.
Recommended setting for all connection work.
Cloning plug
no. 2062452
Max.
2A
F
ext
Connection cable
1)
Figure 45: Wire supply voltage for CLV69x-xxx0 (without heating)
6
ELECTRICAL INSTALLATION
52
O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK