Connection cable 1:1
1)
Wire RS-422 data interface of the CLV69x in the CDB650-204 connection module
CLV69x CDB650-204
Host
1
.
.
.
TD+
TD‒
RD+
RD‒
RD+
RD‒
TD+
TD‒
GND
GND
GND
11
12
1
5 5
6
11
12
6
33
T+
43
T‒/TxD
34
R+
44
R‒/RxD
42
GND
6
Shield
RS-422 RS-422
422
485
S6: RS
ON
OFF
S7: Term 485
S6
422
S7
OFF
120 Ω
485
S7: Term 485
Set to ON, if termination of the
RS-422 receiver in the CLV69x is
needed to improve the interference
distance on the cable.
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
M12,
17-pin,
A-coded
For CLV69x-xxx0 (without heating):
no. 6052286 (2m)
no. 6051194 (3m)
no. 6051195 (5m)
For CLV69x-xxx1 (with heating):
no. 6053230 (2m)
no. 6053231 (3m)
no. 6053232 (5m)
1) Dependent on type
Figure 48: Wire serial host interface RS-422
NOTE
Use of the RS-422 data interface:
The relevant interface drivers for the device comply with the standard for RS-422 and RS-485.
Activation of the interface in the device with the SOPAS ET configuration software (point-to-point).
The connection shown above is configured for operation of the host with permanently activated drivers (often
described as “RS-422 operation”), i.e. not RS-485 bus operation.
ELECTRICAL INSTALLATION 6
8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x
55
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV69x and is the answer not in the manual?

SICK CLV69x Specifications

General IconGeneral
BrandSICK
ModelCLV69x
CategoryBarcode Reader
LanguageEnglish

Related product manuals