EasyManuals Logo

SICK CLV69x User Manual

SICK CLV69x
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Wire supply voltage for CLV69x-xxx0 in the CDM420-0006 connection module
CLV69x-xxx0 (without heating)
CDM420-0006
U
V
U
V
2
1
1
5
5
Shield
1 +24V
2 GND
+24V*
GND
S1
F
Shield
D-Sub-HD
female
connector, 15-pin
M12 male connector,
17-pin, A-coded
GND
.
.
.
.
.
.
.
.
.
ON
OFF
S1 : POWER
DC 18V ... 30V
+24V*
POWER
U
V
= DC 18V ... 30V at terminal +24V =
U
V
at terminal +24V* after switch S1, protected by internal fuse F
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
6110 5
1115
Switch S1:
ON:
supply voltage U
V
(+24V) switched via fuse as U
V
(+24V*)
to CDM420-0006 and CLV69x.
U
V
(+24V*) can also be engaged at terminal 29 and 39.
OFF:
CDM420-0006 and CLV69x separated from supply voltage.
Recommended position for all connection types.
For CLV69x-xxx0 (without heating):
No. 2049764 (0.9m)
no. 2055419 (2m)
no. 2055420 (3m)
No. 2055859 (5m)
1) Adapter cable
Cloning plug
No. 2062452
“HOST/AUX/I/O”
connection
Max.
2A
F
Adapter cable
1)
Figure 57: Wire supply voltage for CLV69x-xxx0 (without heating)
6
ELECTRICAL INSTALLATION
64
O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK
Subject to change without notice

Table of Contents