Wire “Sensor 1 and 2” switching inputs of the CLV69x in the CDM420-0006 connection module
CLV69xCDM420-0006
PNP sensor
U
V
U
V
U
V
GND
GND
SensGND
3.32K
6.64K
Sensor Z
U
e
Y2
9
a) Sensor supplied by CDM420-0006
a) Switch supplied by CDM420-0006
2
2)
1
Y1
15
1
5
Out
+24V*
GND
S6
e.g. photoelectric sensor
ON
OFF
S6 : SGND-GND
Characteristic data of the switching inputs “Sensor 1 and 2”
Current at the input starts the assigned function,
e.g. start reading cycle.
(CLV69x default settings:
logic active high, debouncing 10mm)
– Opto-decoupled, reverse polarity protected
– Can be wired with PNP output of a sensor
– SensGND is the common insulated
reference potential for all switching inputs
Low: U
e
≤ 2 V; I
e
≤ 0.3mA
High: 6V ≤ U
e
≤ 32V;
0.7mA ≤ I
e
≤ 5mA
Switching
behavior
Properties
Electrical values
Switch S6 : SGND-GND
ON: connect GND of the sensor to the GND of
the CDM420-0006/CLV69x.
OFF: sensors connected volt-free to CDM420-
0006/CLV69x.
Reference potential valid for all “Sensor 1 and 2”
switching inputs and optionally “AUX In 1 and 2”
Shield
D-Sub-HD female
connector, 15-pin
M12 male
connector,
17-pin, A-coded
GND
.
.
.
X
Name
37
SGND
6
Shield
39
+24V*
U
e
= max. 32V
+24V*
CDM420-0006
GND
S6
ON
OFF
S6 : SGND-GND
Shield
38
Sensor 1
37
SGND
6
Shield
39
+24V*
b) Sensor connected volt-free and externally supplied
+24V*
CDM420-0006
PNP sensor
U
V
GND
Out
GND
S6
e.g. photoelectric
sensor
ON
OFF
S6 : SGND-GND
U
V ext
Shield
38
Sensor 1
37
SGND
6
Shield
39
+24V*
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
6110 5
1115
d) Switch connected volt-free
and externally supplied
Connection of the switch as under b)
Functional assignment for switching inputs via
SOPAS-ET configuration software
For CLV69x-xxx0 (without heating):
No. 2049764 (0.9m)
No. 2055419 (2m)
No. 2055420 (3m)
No. 2055859 (5m)
For CLV69x-xxx1 (with heating):
No. 2061480 (2m)
No. 2061605 (3m)
No. 2061481 (5m)
1) Dependent on type
CDM420-0006
CLV69x
Terminal X
38
28
Name
Sensor 1
Sensor 2
Pin Y1
14
4
Pin Y2
10
15
Sensor Z
Sensor 1
Sensor 2
Adapter cable
1)
2) Pin 2 in CLV69x-xxx1
(with heating) not