EasyManuals Logo

SICK CLV69x User Manual

SICK CLV69x
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
U
e
= max. 30V
Wire switching inputs “Ext. input 1 and 2” of the CLV69x on the CDM420-0006 connection module
CLV69x
CDM420-0006
PNP sensor
U
V
GND
3.32K
6.64K
U
e
Out
GND
S6
e.g. photoelectric sensor
CMC600
a) Sensor supplied by CDM420-0006
Serial Aux
(RS-232)
ON
OFF
S6 : SGND-GND
No
YES
S8 : CMC
17
SGND
8
Shield
39
+24V*
X
Name
+24V*
The CMC600 automatically transmits the
output states of its physical “Aux In 1 and
2” inputs to the serial Aux interface of the
CLV69x via the connecting cable using
software.
The CLV69x translates the statuses to its
logical “External input 1 and 2“ inputs.
“External
input 1,
input 2”
Characteristic data of switching inputs “Ext. input 1 and 2”
Current at the input starts the assigned
function, e.g. start reading cycle. (CLV69x
default settings: logic active high, deboun-
cing 10mm)
– Opto-decoupled, reverse polarity protected
– Can be wired with PNP output of a sensor
– SensGND is the common insulated
reference potential for all switching inputs
Low: U
e
≤ 2V; I
e
≤ 0.3mA
High: 6V ≤ U
e
≤ 30V;
0.7mA ≤ I
e
≤ 5mA
Switching
behavior
Properties
Electrical
values
a) Switch supplied by CDM420-0006
CDM420-0006
U
e
GND
S6
CMC600
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17
SGND
8
Shield
39
+24V*
18
Aux In 1
+24V*
SensGND
CDM420-0006
PNP sensor
U
V
GND
Out
GND
S6
e.g. photoelectric
sensor
U
V ext
U
e
CMC600
b) Sensor connected volt-free and externally supplied
No
YES
S8 : CMC
ON
OFF
S6 : SGND
17
SGND
8
Shield
39
+24V*
18
Aux In 1
+24V*
SensGND
SensGND
d) Switch connected volt-free
and externally supplied
Connection of the switch as under b)
Functional assignment for switching inputs
via SOPAS-ET configuration software
CDM420-0006
Terminal X
18
19
Name
Aux In 1
Aux In 2
Switch S6 : SGND
ON: connect GND of the switching inputs with
the GND of the CDM420-0006/CMC600.
OFF: sensors connected volt-free to the switching
inputs of the CDM420-0006/CMC600.
Reference potential valid for all “Sensor 1 and 2”
switching inputs and optionally “AUX In 1 and 2”.
Figure 64: Wiring switching inputs “External input 1 and 2”
ELECTRICAL INSTALLATION
6
8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x
71
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV69x and is the answer not in the manual?

SICK CLV69x Specifications

General IconGeneral
BrandSICK
ModelCLV69x
CategoryBarcode Reader
LanguageEnglish

Related product manuals