Distance [m] Signal level
PL240DG PL560DG PL880DG
50 7500 7500 7500
100 6200 6200 6200
200 5000 5000 5000
500 1600 3300 3400
1000 850 1500 1850
1500 - 450 800
A step-by-step process is recommended for alignment:
1. Bring the distance sensor and measuring object close together.
2. Align the distance sensor so that the light spot of the measuring laser hits the cen‐
ter of the reflector or the natural object or the level maximum for this distance is
displayed.
3. Increase the distance between the distance sensor and measuring object. The
light spot must continue to hit the center of the reflector or the natural object or
the level maximum for the respective distance must be displayed.
Proceed as follows to align the distance sensor:
PWR
In1/Q1
QA/Q2
Q3
Q4
In2
LNK
BUS
3
4
1
2
X
Figure 15: Align the distance sensor with alignment bracket in the X-direction
5
MOUNTING
40
O P E R A T I N G I N S T R U C T I O N S | DT1000 and DL1000 8019329/12TZ/2019-03-28 | SICK
Subject to change without notice