7.4.2 IO interfaces
Digital inputs
•
Digital input: see "Configuring the switching input", page 68
•
Switching function: see "Defining the active state for digital input", page 68
Digital outputs
•
Switching point distance: see "Defining the switching point for distance value (dis‐
tance to object)", page 61
•
Distance switching window: see "Defining the switching window for the distance
value", page 63
•
Switching point object speed: see "Defining the switching point for the object
speed value", page 64
•
Service function switching event: see "Assigning a switching event to the service
functions", page 66
•
Monitoring direction speed: see "Defining the monitoring direction for the object
speed value", page 65
•
Distance switching point hysteresis: see "Defining the switching hysteresis for the
distance value", page 62
•
Distance window hysteresis: see "Defining the switching window hysteresis for the
distance value", page 63
•
Object speed hysteresis: see "Defining the switching point hysteresis for the object
speed value", page 64
•
Signal logic: see "Defining the switching point active state for the distance value",
page 62 / see "Defining the switching window active status for the distance
value", page 64 / see "Defining the switching point active state for the object
speed value", page 65
Analog output
•
Analog output QA: see "Configuring the QA analog output", page 67
RS 422 connection
•
Data transmission rate: see "Defining the RS-422 data transmission rate",
page 71
•
Data format: see "Defining the RS-422 data format", page 72
•
Protocol: see "Defining the RS-422 data protocol", page 74
•
Distance value resolution: see "Defining the distance value resolution for the
RS-422 data transfer", page 74
•
Resolution speed value: see "Defining the speed value resolution for the RS-422
data transfer", page 74
•
Transmission mode: see "Setting the continuous RS-422 output", page 72
SSI connection
•
SSI coding: see "Defining SSI coding", page 75
•
Distance value resolution: see "Defining the distance value resolution for the SSI
data transfer", page 75
7.4.3 Device information
•
Operating hour counter: see "Operating time display", page 51
•
Operating temperature: see "Temperature display", page 50
•
Switching events: see "Retrieving the counter readings of switching events",
page 78
•
IP network configuration: see "Entering an IP address", page 76
7 OPERATION
52
O P E R A T I N G I N S T R U C T I O N S | DT1000 and DL1000 8019329/12TZ/2019-03-28 | SICK