3.5.14.2 Switching field width
The width of the switching field must cover the width of the vehicle and take into
account the supplements for the measurement error.
The switching field width SB can be calculated using the following formula (guideline
values based on a pixel calculation):
SB = FB + 2 × (ZG + ZR)
FB = Vehicle width
ZG = General safety supplement for the LiDAR sensor = 100 mm
ZR = Supplement for application-related influences or the selected application parame‐
ters
PRODUCT DESCRIPTION 3
8020494/1AZF/2021-05-10 | SICK O P E R A T I N G I N S T R U C T I O N S | MRS1000
31