NOTE
If the inspection window is scratched or damaged (cracked or broken), the window must
be replaced. Contact SICK Service to arrange this.
Cleaning procedure
CAUTION
Laser and LED safety
See "Operational safety and particular hazards", page 9 for information regarding laser
and LED safety.
►
Switch off the device for the duration of the cleaning operation. If this is not
possible, use suitable laser protection goggles. These must absorb radiation of the
device's wavelength effectively.
►
Plastic window: Clean the inspection window only with a clean, damp, lint-free
cloth, and a mild anti-static lens cleaning fluid.
Cleaning the housing
To ensure that heat is adequately dissipated from the device, the housing surface must
be kept clean.
►
Clear the build-up of dust on the housing with a soft brush.
8.3 Back up and restore
Use the PLxManager tool to create a backup of a device and to restore a backup.
Please see "PLxManager", page 70 on how to download PLxManager and find instruc‐
tions on how to create a backup and restore PLOC2D.
8 MAINTENANCE
68
O P E R A T I N G I N S T R U C T I O N S | PLOC2D 4.1 8020736/1K3Z/2023-06 | SICK
Subject to change without notice