EasyManua.ls Logo

SICK RFU63 Series - Page 115

SICK RFU63 Series
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
CMC600 parameter cloning module (optional)
4
Auxiliary interface “AUX”
5
Male connector, D-Sub, 9-pin
6
Name of the digital output
7
e.g. PLC (programmable logic controller)
8
SCANNER = Device
9
Female connector, D-Sub-HD, 15-pin
ß
Device to be connected
à
The optional CMC600 parameter cloning module is required in the connection module in order to use the additional
external digital inputs and outputs of the device (highlighted in gray).
14.6.3 Connecting supply voltage for the device in CDM420-0006
Device = RFU630-131xx, RFU630-041xx
Device
3CDM420-0006
V
S
2
1
1
5
5
Shield
1 +24 V
2 GND
+24 V*
GND
S1
F
Shield
GND
.
.
.
.
.
.
.
.
.
ON
OFF
S1 : POWER
+24 V*
POWER
V
S
GND
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
V
S
- +24 V -
F
S 1
- +24 V*
5 4
Cable 2
V
s
1
110
15
6
11
5
Figure 56: Connecting supply voltage for the device in CDM420-0006 connection module.
1
Supply voltage V
S
2
Adapter cable with male connector, D-Sub-HD, 15-pin and female connector, M12, 17-pin, A-coded
3
Device
4
Device: male connector, M12, 17-pin, A-coded
5
Connection module: female connector, D-Sub-HD, 15-pin
Function of switch S1
Table 47: Switch S1: Power
Switch setting Function
ON Supply voltage +24V connected to CDM420-0006 and device via fuse
as +24V* supply voltage
Supply voltage +24V* can be additionally tapped at terminals 29 and
39
OFF CDM420-0006 and device disconnected from supply voltage
Recommended setting for all connection work
ANNEX 14
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
115
Subject to change without notice

Table of Contents

Other manuals for SICK RFU63 Series

Related product manuals