EasyManua.ls Logo

SICK RFU63 Series - Page 116

SICK RFU63 Series
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.6.4 Wiring serial host interface RS-232 of the device in the CDM420-0006
Device = RFU630-131xx, RFU630-041xx
Device 1 CDM420-0006 Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
12
1
9
7
6
34
T/TxD
35
R/RxD
36
GND
6
Shield
RS-232 RS-232
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFFON
2
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
110
15
6
11
5
4 3
Figure 57: Wiring data interface RS-232 of the device in connection module CDM420-0006.
1
Device
2
Adapter cable with male connector, D-Sub-HD, 15-pin and female connector, M12, 17-pin, A-coded
3
Connection module: female connector, D-Sub-HD, 15-pin
4
Device: male connector, M12, 17-pin, A-coded
NOTE
Activate the RS-232 data interface in the device with a configuration tool, e.g., the
configuration software SOPASET.
14.6.5 Wiring serial host interface RS-422 of the device in the CDM420-0006
Device = RFU630-131xx, RFU630-041xx
14 ANNEX
116
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK RFU63 Series

Related product manuals