Procedure:
1. Connect the communication interface (e.g., Ethernet) of the device directly to the
computer using a cable 9.
2. If external antennas are used (maximum 3, e.g., RFA630-000), these must be
connected to the antenna inputs of the device using connecting cables à.
3. Connect "Connection 1" (male connector, M12, 17-pin, A-coded) of the device to
the corresponding female connector on the connection module using a cable ß.
4. If necessary, connect a trigger sensor for the external read cycle, such as a
photoelectric retro-reflective sensor, to the “Sens/IN 1” (CDB650-204) or “Sensor
1” (CDM420-0006) digital input of the connection module. For CDB650-204:
see "Wiring digital inputs of the device in the CDB650-204", page 106. For
CDM420-0006: see "Wiring digital inputs of the device in the CDM420-0006",
page 119.
5. Supply the device with the required voltage depending on the length of the con‐
necting cable ß, see "Supply voltage", page 51.
After successful initialization, the “Device Ready” LED lights up green.
6. Switch on computer.
7. Start Windows.
RFU630-041xx (without internal antenna)
...
...
1
2
V
S
GND
"Ethernet" (AUX 2)
...
1 4
RFU630-
041xx
"Power/Serial Data/CAN/I/O"
(AUX 1, Host 1)
External antennas á
8
Cable 9
Cable ß
Cable à
2
3
Connection
module
EthernetEthernet
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Cable 4
"USB" (AUX 3),
for temporary use only 6
SerialSerial
USBUSB
SOPAS ETSOPAS ET
Computer
"Serial RS-232" (AUX 1) 5
Cable 7
SGND
+24 V*
37 38 39
Sensor 1
Trigger
sensor
1
Out
GND
V
S
CDM420-0006
SGND
U
IN
*
10 11 12
Sens/IN 1
Trigger
sensor
1
Out
GND
V
S
CDB650-204
Figure 30: Electrical connection block diagram for the RFU630-041xx with optional connection
module: commissioning
1
Trigger sensor for external read cycle
2
Supply voltage V
S
3
Connection module CDB650-204 or CDM420-0006
4
Null modem cable with two female connectors, D-Sub, 9-pin, crossed TxD and RxD
5
Serial RS-232, alternative to USB or Ethernet AUX port
6
USB, alternative to serial RS-232 or Ethernet AUX port The USB interface must only be
used temporarily as a servicing interface.
7
Adapter cable with male connector, USB, type Micro-B and male connector, USB, type A
8
Configuration with SOPAS ET, prepared representation of the read result, transponder
access or reading diagnostics
9
Adapter cable with male connector, M12, 4-pin, D-coded and male connector, RJ-45,
8-pin
COMMISSIONING 7
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
61
Subject to change without notice