ß
For CDB650: Connecting cable 1:1 with male connector, M12, 17-pin, A-coded and
female connector, M12, 17-pin, A-coded
For CDM420-0006: Adapter cable with male connector, D-Sub-HD, 15-pin and female
connector, M12, 17-pin, A-coded
à
Antenna connecting cable with two male connectors, TNC reverse
á
External antennas, e.g. RFA630-000 (region Europe and possibly other countries)
Procedure:
1. Connect the communication interface (e.g., Ethernet) of the device directly to the
computer using a cable 9.
2. Connect external antennas (maximum 4, e.g. RFA630-000) to the antenna inputs
of the device using connecting cables à. At least one external antenna is
required!
3. Connect "System" (male connector, M12, 17-pin, A-coded) to the corresponding
female connector on the connection module using a cable ß.
4. If necessary, connect a trigger sensor for the external read cycle, such as a
photoelectric retro-reflective sensor, to the “Sens/IN 1” (CDB650-204) or “Sensor
1” (CDM420-0006) digital input of the connection module. For CDB650-204:
see "Wiring digital inputs of the device in the CDB650-204", page 106. For
CDM420-0006 see "Wiring digital inputs of the device in the CDM420-0006",
page 119.
5. Supply the device with the required voltage depending on the length of the con‐
necting cable ß, see "Supply voltage", page 51.
✓
After successful initialization, the “Device Ready” LED lights up green.
6. Switch on computer.
7. Start Windows.
7.1.2 Block diagram: wiring the optional connection module
NOTE
For possible combinations of the device and various connection modules, see table 15,
page 63
7 COMMISSIONING
62
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice