“V
S
“Host 1”
Aux 1”
“Result 2”
“Result 1”
“CAN”
“Sensor 2”
“Sensor 1”
AUX
CAN bus
“Result 1”
“Result 2”
PLC
CDB650-204
Connection module 6
“Host 1”
Aux 1”
RS-232
HOST/PLC
Further data
processing 8
Computer
Configuration
Diagnostics 7
Interfaces 5
“Ethernet” (Host 2/Aux 2)
“USB” (Aux 3)
RS-232/422
Ethernet
USB
“Host 2”
Ethernet
Aux 2”
Aux 3”
“Sensor 2”
“Sensor 1”
“External input 2”
“External input 1”
CMC600
1
2
3
V
S
á
= à
“External output 2”
“External output 1”
Transponder
Device 4
9 ß
Figure 31: Connection of the device to peripherals via CDB650-204 (overview)
1
Start and stop reading pulse (e.g., photoelectric retro-reflective sensor)
2
Application-dependent alternative stop read cycle (e.g. photoelectric sensor) or travel
increment (incremental encoder)
3
Other functions
4
Device
5
Interfaces
6
Connection modules
7
Configuration and diagnostics
8
Data further processing
9
External digital inputs
ß
External digital outputs
à
The parameter cloning module CMC600 is required to use the additional digital inputs
and outputs of the device (highlighted in gray).
á
Supply voltage V
S
Using optional connection modules
Table 15: Possible combinations of device and connection modules
Device Connection on the
device
Connection module Connection cable
RFU630 Male connector, M12,
17-pin, A-coded
CDB650-204 Cable 1:1
1)
CDM420-0006,
CDM420-0007
3)
Adapter cable
2)
1)
Connection cable 1:1 with female connector, M12, 17-pin, A-coded and male connector, M12, 17-pin,
A-coded
2)
Adapter cable with female connector, M12, 17-pin, A-coded and male connector, D-Sub-HD, 15-pin
3)
CDM420-0007: for connecting 2 devices
The supply voltage for the device is protected as follows in the connection modules:
COMMISSIONING 7
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
63
Subject to change without notice