For mobile installation: –25°C to +40°C, for fixed installation:: –35°C to +40°C
...
ð
1 2
1 2
67 14
12
3
4
5
8
9
10
11
13
15
17
16
Figure 37: Adapter cable, part no. 2075220
1
Female connector, M12, 17-pin, A-coded (front view)
2
Figure may differ.
Table 30: Signal assignment of adapter cable with open end
PIN Signal Function Wire color
1 GND Ground Brown
2 V
S
Supply voltage Blue
3 CAN L CAN bus (IN/OUT) White
4 CAN H CAN bus (IN/OUT) Green
5 – – Pink
6 TxD (RS-232), host Host interface (sender) Yellow
7 – – Black
8 – – Gray
9 SensGND Ground for digital inputs Red
10 Sensor 1 Digital input 1 Violet
11 – – Gray-pink
12 RxD (RS-232), host Host interface (receiver) Red-blue
13 Result 1 Digital output 1 White-green
14 Result 2 Digital output 2 Brown-green
15 Sensor 2 Digital input 2 White-yellow
16 Result 3 Digital input 3 Yellow-brown
17 N. c. – White-gray
14.4.2 “POWER” connection to customer-specific connection equipment (voltage supply) or control cabinet
Adapter cable
Part no. 6048319 (10m), 3-wire, unshielded
For RFU630, RFU650
Ambient temperature range:
For fixed installation: –25°C to +80°C
ð
1 2
1 2
67
14
12
3
4
5
8
9
10
11
13
15
17
16
Figure 38: Adapter cable, part no. 6048319 (10m)
1
Female connector, M12, 17-pin, A-coded (front view)
2
Illustration may differ
14 ANNEX
96
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice