Chapter 9 Operating Instructions
UE403
30 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010854/WP71/2012-11-28
Subject to change without notice
Fault diagnosis
9.3 Error displays of the LEDs
T
his chapter explains the meaning of the error displays of the LEDs and how to respond.
Please refer to chapter 3.4 “Status indicators” on page 14.
Display Possible cause Remedying the error
Yellow The yellow LED
on the COM
connection is
not illuminated.
No operating
voltage, or voltage
too low
Switch the connected M4000
off for at least 1 minute and
back on again.
If the error continues to occur:
Check the connection to the
M4000 connected. The UE403
switching amplifier receives it
voltage supply from the ESPE
connected.
Yellow The yellow LED
on the COM
connection is
flashing.
Connection error
or
Check the connection to the
M4000 connected for short-
circuits or cross-circuits.
Check the voltage supply for
overcurrent.
Switch the connected M4000
off for at least 1 minute and
back on again.
If the error continues to occur:
Replace the UE403 switching
amplifier.
Internal error of the
UE403
Carry out an extended
diagnostics with the aid of the
CDS.
If an internal error is diagnosed:
Replace the UE403 switching
amplifier.
9.4 Extended diagnostics
The CDS software (Configuration & Diagnostic Software) supplied with the M4000
Advanced multiple light beam safety device contains extensive diagnostic facilities. It
allows you to narrow down the problem if the error is non-specific or if you experience
usage downtime problems. Detailed information to be found …
in the online help function of the CDS (Configuration & Diagnostic Software).
in the user manual for the CDS.
How to conduct an extended diagnostics of the UE403:
Connect the PC/Notebook in which the CDS has been installed to the UE403 switching
amplifier or to the M4000 Advanced.
Carry out a diagnostics on the M4000 Advanced receiver.
Device symbol M4000 Advanced (receiver) or M4000 Advanced (A/P), context menu
Diagnostics, Display.
Tab.
8
:
Error displays of the
LEDs

Table of Contents