EasyManua.ls Logo

SICK UE403 - Technical specifications; Data sheet

SICK UE403
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions Chapter 10
UE403
8010854/WP71/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 31
Subject to change without notice
Technical specifications
10 Technical specifications
10.1 Data sheet
Minimum Typical Maximum
General system data
Protection class (EN 50178:1998) III
Enclosure rating (IEC 60529)
IP 65
Supply voltage U
V
at the UE403
(via connected ESPE)
19.2 V 24 V 28.8 V
Power consumption 2 A
Type acc. to IEC 61496 Type 4
Housing dimensions See dimensional drawing on page 34.
Weight 0.6 kg
RES/OVR connection
Inputs
1)
: Override, reset, C1, belt stop
11 V 24 V 30 V
Switching voltage HIGH
Input current HIGH 6 mA 10 mA 15 mA
–30 V 0 V 5 VSwitching voltage LOW
Input current LOW –0.5 mA 0 mA 1.5 mA
Actuation time for the control
switch reset or override
200 ms
Output: Reset required
Switching voltage HIGH 15 V 24 V 28.8 V
Output power/current HIGH
(short-circuit protected)
4 W/0.2 A
0 V1 VSwitching voltage LOW (high
resistance)
Flashing frequency
1/s
Output: 24 V DC voltage supply
Supply voltage for reset, override
or C1
15 V 24 V 28.8 V
Supply current for reset, override
or C1
400 mA
2)
1)
As per IEC 61131-2.
2)
Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1 in each case):
max. 1000 mA.
Tab.