Operating Instructions Chapter 10
UE403
8010854/WP71/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 31
Subject to change without notice
Technical specifications
10 Technical specifications
10.1 Data sheet
Minimum Typical Maximum
General system data
Protection class (EN 50178:1998) III
Enclosure rating (IEC 60529)
IP 65
Supply voltage U
V
at the UE403
(via connected ESPE)
19.2 V 24 V 28.8 V
Power consumption 2 A
Type acc. to IEC 61496 Type 4
Housing dimensions See dimensional drawing on page 34.
Weight 0.6 kg
RES/OVR connection
Inputs
1)
: Override, reset, C1, belt stop
11 V 24 V 30 V
Switching voltage HIGH
Input current HIGH 6 mA 10 mA 15 mA
–30 V 0 V 5 VSwitching voltage LOW
Input current LOW –0.5 mA 0 mA 1.5 mA
Actuation time for the control
switch reset or override
200 ms
Output: Reset required
Switching voltage HIGH 15 V 24 V 28.8 V
Output power/current HIGH
(short-circuit protected)
4 W/0.2 A
0 V1 VSwitching voltage LOW (high
resistance)
Flashing frequency
1/s
Output: 24 V DC voltage supply
Supply voltage for reset, override
or C1
15 V 24 V 28.8 V
Supply current for reset, override
or C1
400 mA
2)
1)
As per IEC 61131-2.
2)
Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1 in each case):
max. 1000 mA.