Operating Instructions Chapter 10
UE403
8010854/WP71/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 33
Subject to change without notice
Technical specifications
Minimum Typical Maximum
Operating data
Cable length between ESPE and
UE403
10 m
Wire cross-section 0.34 mm
2
Cable resistance/per cable 0.5
Ambient operating temperature –30 °C +55 °C
Air humidity (non-dewing) 15%95%
Storage temperature –30 °C +70 °C
Vibration resistance 5 g, 10–55 Hz acc. to IEC 60068>2>6
Shock resistance 10 g, 16 ms acc. to IEC 60068>2>29
Environmental data
Housing Aluminium die-cast (powder coated)
Connector strip Polyamide
Packaging Corrugated cardboard
Circuit boards Glass-fibre reinforced epoxy resin with flame
retarding agent TBBPA