What to do if Siemens 6EP4135-0GB00-0AY0 reports a defective battery?
- Kkaren95Aug 30, 2025
If your Siemens UPS indicates a defective battery, check the fuse and the battery voltages.
What to do if Siemens 6EP4135-0GB00-0AY0 reports a defective battery?
If your Siemens UPS indicates a defective battery, check the fuse and the battery voltages.
What does unknown parameter mean on Siemens UPS?
Attempting to set a parameter that is not known by Siemens DC UPS.
What does insufficient charge level mean on Siemens 6EP4135-0GB00-0AY0?
The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.
What does battery SoH test mean on Siemens 6EP4135-0GB00-0AY0 UPS?
Battery "State of Health" tests (SoH) are performed on your Siemens UPS.
What does wrong battery number mean on Siemens 6EP4135-0GB00-0AY0?
Attempting to retrieve data about a battery which does not exist or is not connected to your Siemens UPS.
What does corrupt data record mean on Siemens 6EP4135-0GB00-0AY0 UPS?
Error during software update on your Siemens UPS - try to update the software again.
Why Siemens 6EP4135-0GB00-0AY0 input voltage is too high?
Siemens DC UPS is not operational.
Why is the battery not available on my Siemens Power Supply?
The Siemens Power Supply is attempting to access a battery that is not available because it was never connected, or communication with this battery was interrupted.
What does battery temperature high mean on Siemens 6EP4135-0GB00-0AY0 UPS?
The Siemens UPS battery temperature is too high, which will shorten the battery life.
How to fix Siemens UPS device temperature too low?
If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
Output Voltage | 24 V DC |
---|---|
Output Current | 5 A |
Output Frequency | 50/60 Hz |
Battery Voltage | 24 V DC |
Battery Type | Lead-acid |
Efficiency | > 90% |
Protection Class | IP20 |
Type | UPS |
Operating Temperature | 0°C to +40°C |
Storage Temperature | -20°C to +60°C |
Essential safety notes for operating electrical devices and preventing personal injury.
Using SIMATIC STEP 7 in TIA Portal for SITOP UPS1600 configuration.
Introduction to the SITOP UPS Manager for monitoring and configuration.
Procedures for mounting and removing the SITOP UPS1600.
Procedures for mounting and removing SITOP UPS1100 battery modules.
Procedures for connecting input, output, and battery terminals.
Step-by-step guide for replacing batteries in SITOP UPS1100.
Safety class and degree of protection details.