Descriptions of functions
10.3 Communication according to PROFIdrive
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
447
Error
value
Meaning
Remark
Additional
info
0x6B Write access for the enabled
controller.
Write access is possible while the device is in the "Controller
enable" state.
Pay attention to the parameter attribute "changeable" in the
SINAMICS DCM List Manual (C1, C2, U, T).
0x6C
Parameter %s [%s]: Unknown unit.
0x6D Parameter %s [%s]: Write access
only in the commissioning state,
encoder (p0010 = 4).
0x6E Parameter %s [%s]: Write access
only in the commissioning state,
motor (p0010 = 3).
0x6F Parameter %s [%s]: Write access
only in the commissioning state,
power unit (p0010 = 2).
0x70 Parameter %s [%s]: Write access
only in the quick commissioning
mode (p0010 = 1).
0x71 Parameter %s [%s]: Write access
only in the ready mode (p0010 = 0).
0x72 Parameter %s [%s]: Write access
only in the commissioning state,
parameter reset (p0010 = 30).
0x73 Parameter %s [%s]: Write access
only in the commissioning state,
Safety (p0010 = 95).
0x74 Parameter %s [%s]: Write access
only in the commissioning state, tech.
application/units (p0010 = 5).
0x75 Parameter %s [%s]: Write access
only in the commissioning state
(p0010 not equal to 0).
0x76 Parameter %s [%s]: Write access
only in the commissioning state,
download (p0010 = 29).
0x77 Parameter %s [%s] must not be
written during download.
0x78 Parameter %s [%s]: Write access
only in the commissioning state, drive
configuration (device: p0009 = 3).
0x79 Parameter %s [%s]: Write access
only in the commissioning state,
define drive type (device: p0009 = 2).