Siemens Actuators SAX.., SAY.., SAV.., SAL.. for valves CE1P4040en
Building Technologies Engineering 2018-12-05
Stroke 20 mm 40 mm
Typical applications Stroke actuators Data Sheet Positioning force 800 N 1600 N
· Heating plants
· Ventilation and air conditioning
plants
· Heat generation
· Heat distribution
· District heating plants
SAX..
SAV..
8)
N4501
N4503
SAX.. SAV..
Valves Basic Doc. (P4030) Δp
max
5)
[kPa]
Δp
max
[kPa]
Δp
max
5)
[kPa]
Δp
max
[kPa]
Valves Data Sheet Valve type DN k
vs
[m
3
/h]
PN16 N4403 VXF42.15-..
2)
15 1.6 / 2.5 / 4
100
400
- -
VXF42.20-6.3
20 6.3
VXF42.25-..
2)
25 6.3 / 10
VXF42.40-..
2)
40 16 / 25
100 400VXF42.50-..
2)
50 31.5 / 40 300
VXF42.65-..
2)
65 50 / 63
50
150
VXF42.80-..
2)
80 80 / 100 75
50
225
VXF42.100-..
2)
100 125 / 160
- -
125
VXF42.125-..
2)
125 200 / 250 90
-10…130 °C
4)
VXF42.150-..
2)
150 315 / 400 60
PN16
N4404
VXF43.65
-
63
65
63
- -
100
400
VXF43.80-100 80 100
50
225
VXF43.100
-
160
100
160
125
VXF43.125
-
250
125
250
90
-20…130 °C
4)
VXF43.150-400 150 400 60
PN25/16
6)
N4405
VXF53.15
-
..
2)
15
1.6 / 2,5 / 4
200
1200
- -
VXF53.20-6.3 20 6.3
VXF53.25-..
2)
25 6.3 / 10
VXF53.32-16 32 16 750
VXF53.40-..
2)
40 16 / 25 500
200
1150
VXF53.50-40 50 40 100 300 700
PN25
6)
VXF53.65-63 65 63
- -
100 400
VXF53.80
-
100
80
100
50
225
VXF53.100
-
160
100
160
125
VXF53.125
-
250
125
250
90
-20…130 °C
4)
VXF53.150-400 150 400
75
PN16 N4463 - VXG41.1301
3)
15 1.6
-
800
- -
- VXG41.1401
3)
15 2.5
VXG41.15 VXG41.1501
3)
15 4
VXG41.20 VXG41.2001
3)
20 6.3
VXG41.25 VXG41.2501
3)
25 10
VXG41.32 VXG41.3201
3)
32 16
VXG41.40 VXG41.4001
3)
40 25 525
-25…130 °C
4)
VXG41.50 VXG41.5001
3)
50 40 300
1)
Insert running number instead of k
vs
value
2)
.. = insert k
vs
value
3)
With tight bypass; VXG41.1301 and VXG41.1401: use only SAX61.., SKD32.50 or SKD82.50.
4)
For media temperatures > 130 °C use electrohydraulic actuators SKD.. (N4561), SKB.. (N4564).
5)
Δp
max
= max. permissible differential pressure in diverting mode
6)
DN 15…50: Flange dimensions for PN 16 and PN 25
DN 65…150: Flange dimensions only for PN 25
7)
Valves no longer in the active sale
8)
SAV..: This product line of actuators might not be available in all countries. Please talk to your local
contact or consult your local internet pages of www.buildingtechnologies.siemens.com.
4040U32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Acvatix SAX Series and is the answer not in the manual?

Siemens Acvatix SAX Series Specifications

General IconGeneral
BrandSiemens
ModelAcvatix SAX Series
CategoryController
LanguageEnglish

Related product manuals