2. Highlight the 'FG2004' element in the 'Hardware' task card.
3. Assign the required IP address to the 'FG2004' element in the 'Network' tab
under 'IP address'. Information: All setting options in the other tabs of the
detail editor have no influence on the behavior of the Cloud Gateway.
4. Go to the 'Operation' task card.
5. Highlight the following element in the Station that needs to have visibility of the
'FG2004' Station: 'PMI' > 'Standard visibility'
6. Assign the 'FG2004' Station to the 'Standard visibility' element using 'Assign'.
Optional: If required, assign visibility of the 'FG2004' Station to other stations
with a 'PMI'.