Current value of a time T
If you view a time T in parameterization mode, it looks like this:
B01:T
T
a
= 00:00m
T = 12:00m
Time T set
Current time T
a
You can change the set time T (see ”Changing a parameter”).
Current value of the clock
If you view a cam of a clock in parameterization mode, it looks like this,
for example:
B02:No1
Off=10:00
Day = Su
The switching state of the clock
is displayed:
On =09:00
1
The clock is off (state ’0’ at the
output)
The clock is on (state ’1’ at the
output)
1
0
LOGO! displays the switching state of the clock rather than the switching
state of a cam. The switching state of the clock depends on all three cams
(No1, No2 and No3).
Current value of a counter (Par)
If you view the parameter of a counter in parameterization mode, it looks
like this:
B03:Par
Cnt = 0028
Par = 0300
Switching threshold
Current count value
Parameterizing LOGO!