7ML19985CN01 Milltronics SF 500 - INSTRUCTION MANUAL Page 93
mmmmm
Parameters
Entry:
1 = weight
f
3 = ECal
P003 Number of Load Cells
Siemens Milltronics flowmeters are available in models of one or two load cell design.
Select the number of load cells corresponding to the flowmeter connected.
If using the optional remote LVDT conditioner card, for LVDT based scales, select the “1”
value.
Entry:
Enter the number of load cells: 1
f
or 2.
P004 Rate Measurement System
Selects system of measurement used, either imperial or metric.
Entry:
1 = imperial
2 = metric
f
P005 Design Rate Units
Determines the units for programming and measurement.
Changing this parameter does not affect the rate parameter (P011). This parameter
should be re-entered for conformity in units.
t = 1000 kg
LT= 2240 lb.
T= 2000 lb.
imperial - P004 = 1 metric - P004 = 2
entry:
1
f
=
T/h (tons / hour) t/h (tonnes / hour)
2 =
LT/h (long tons / hour) kg/h (kilograms / hour)
3 =
lb/h (pound / hour) kg/min (kilograms / minute)
4 =
lb/min (pounds / minute)