7ML19985CN01 Milltronics SF 500 - INSTRUCTION MANUAL Page 109
mmmmm
Parameters
P415 Local Set Point Value
Sets the local set point (P415-01 / 02), in engineering units, for the corresponding PID
system (1 or 2) when in auto mode. For the external process variable, the set point is
shown is %. (
f
= 0.000)
P416 External Setpoint
Displays the external setpoint (P416-01 / 02), in engineering units, for the corresponding
PID system (1 or 2). For the external process variable, the setpoint is shown in %.
If the setpoint is external (P414 = 1 or 2), then this parameter displays the setpoint value
that is being input, either mA input 1 or 2.
P418 Remote Setpoint Ratio
Sets the remote setpoint ratio (P418 –01/02) for the corresponding PID system (1 or 2)
when P414 = 1 or 2. (
f
= 100)
The remote setpoint ratio scales remote setpoint input by the set percentage. A value of
100 means that the setpoint is 100% of the mA input.
Batch Control (P560 – P568)
The following parameters are specific to the use of the SF 500 as a batch controller. P564-
P568 is accessible only when Count Up (1) is selected.
P560 Batch Mode Control
Enables the batch control function. Batch control is count up.
Entry:
0 = OFF
f
1 = count up
P564 Batch Setpoint
Sets the batch total. When the amount of material delivered reaches this point, the batch
relay contact opens (P100) to signal the end of the batch. (
f
= 0.000)
Enter the setpoint of the units of weight selected (P005).