2.6 Configuring diagnostic settings
Buffer Mechanism
In buffer mechanism, there are two options:
Default Buffer Mechanism: It provides parallel upload from cache and real time data. It
prioritises newest data to old data while storing (works as a last in, first out (LIFO))
Chronological Buffer Mechanism: It is chronological upload of data. If "Chronologic Upload" is
selected, the buffer mechanism will prioritise oldest data to new data (works as first in, first
out (FIFO)).
You can configure the buffer behavior from "Network and Diagnostic Settings" screen.
If the buffer behavior is changed, it will restart the data collection process and this
process will take few minutes.
Data loss
The data collection will be stopped during the time of buffer behavior change. The
amount of data collection is stopped for few minutes, it depends on restart of the
device. It may take longer time on slow devices like, IoT2040.
To perform a buffer behavior change proceed as follows:
1. In "Asset" tab, select the asset.
2. Open "MindConnect" plugin.
3. Click , next to "Onboarding Status".
4. In "Buffer Behavior" section, select "Chronological Upload".
Overview of onboarding MindConnect IoT2040
2.6 Configuring diagnostic settings
MindConnect IoT2040
System Manual 8/2023 16