The network and SAL settings will be reset to their initial state on MindConnect IoT2040.
All SAL and script logging files will be deleted.
Load new firmware on your MindConnect IoT2040
1. Download the firmware ZIP file from Siemens Industry Online Support Page.
Firmware download MindConnect IoT2040
2. Unzip the firmware on your local machine.
3. Copy the unzipped files to a USB stick.
4. Insert the USB stick into the MindConnect IoT2040 and wait until the firmware update is
complete.
Update carried out: ERROR LED flashes orange
MindConnect IoT2040 reboots
MAINT LED flashes orange for a few seconds
RUN LED orange (not connected to Industrial IoT)
5. Disconnect the USB stick.
5.2 Firmware update in Asset Manager for MindConnect IoT2040
In Asset Manager, you can update the firmware of your MindConnect IoT2040.
Outdated version
Please keep your firmware always updated.
Data loss
Please note that data loss can occur during the time of the firmware update. The
amount of data loss depends on the reading and uploading cycle.
To perform a firmware update, follow these steps:
1. Select the asset in the "Asset" tab.
2. Open the MindConnect plugin.
3. Click next to "Firmware" on the button .
4. Accept the terms and conditions.