Firmware update for Mindconnect IoT 2040
5
5.1 Manual firmware update of MindConnect IoT2040
To prepare your MindConnect IoT2040 for V3 please follow the next two steps:
Set MindConnect to factory settings
Load new firmware on your MindConnect IoT2040
Set MindConnect to factory settings
This procedure is only necessary for boxes that were already connected to V2
(SAP). V1 cannot be upgraded.
1. Set the MindConnect back to factory settings.
2. Create a ConBox_Commands.json file with your favorite code editor.
Content of "ConBox_Commands.json":
{
"Commands": [
{
"Cmd": "DoFactoryReset",
"DeviceID": "MindConnectID"
}
]
}
MindConnectID has to be replaced with the serial number of the device.
3. Copy the extracted/unzipped fw.tar file to a USB stick (fat32 formatted).
4. Plug the USB stick in the MindConnect hardware.
The MindConnect will be restarted automatically.